Ensure all valves are capped.
Duct air leak test procedure.
Test apparatustest apparatus duct leakage test system consists of duct leakage test system consists of.
Conduct multi zone pressurization leakage test.
The above test procedure describes how to determine total duct leakage or how much leakage there is.
The hvac air duct leakage test manual provides practical and detailed procedures for conducting leakage tests.
If the system is short of refrigerant decant the remainder of the charge and replace the line tap with a schrader before re processing the system.
1 blower with speed control vfd to generate range of pressure flowrange of pressure flow 2 flow measuring devices flow grid flow station high flow flow grid flow station high flow orifice plate low flow.
This includes areas like unconditioned attics garages and crawlspaces.
Total duct leakage test in the previous page on the basic duct leakage testing procedure we said that you pressurize the duct system and measure the airflow through the fan.
The only time duct testing is required is when parts of the hvac system are outside of the conditioned envelope.
A third test method.
Apparent differences of about ten percent between fan delivery and sum of airflow measurements at terminals do not necessarily mean poor sealing and excess leakage.
For more information see the real zero guide to the 13 most common leaks.
To find the total duct leakage that s basically all you do.
Figure 5 1l from the 2012 smacna hvac air duct leakage test manual shows the allowable leakage as a function of duct leakage classification and static pressure in the duct.
Measure the airflow through the fan with the duct system at pressure.
Contains updates to the expected leakage rates for ductwork constructed to the smacna hvac duct construction standards metal flexible duct leakage test procedures recommendations on use of leakage testing types.
Leakage class can be calculated using equation 3 but needs to be specified if duct air leakage tests are required.
If any supply or return duct chases flexible lines or air handler units are in these areas by iecc 2015 code a duct leakage test is required.
This american national standard ansi smacna 016 2012 covers revised leakage criteria and builds on the proven methods for testing ductwork for air leaks from the first edition.
The basic idea behind using a duct leakage tester to test for duct leakage is.
Use the line tap to access the system to diagnose problem.
Another form of duct leakage to outside uses a blower door to measure the total amount of.
Potential accuracy of flow measurements should be evaluated.
Use a calibrated fan to pressurize the duct system.